SPRINKLER SYSTEMS
Browse by Categories
Series TY-B Sprinklers
Available in multiple configurations to suit different installation needs:
Orientations: Upright, pendent, recessed pendent, horizontal sidewall, recessed horizontal sidewall, and vertical sidewall
K-Factor: Up to 8.0 for efficient water flow
Temperature Rating: Up to 360°F
Response Type: Standard response
Features
UL and C-UL Listed; FM, NYC, LPCB, and VdS Approved
For 5.6 K-Factor, horizontal and vertical sidewall sprinklers (TY3451, TY3351), see TFP161 for technical information and listing details
For 5.6 K-factor, upright and pendent sprinklers (TY315, TY325), see TFP152 for technical information and listing details
For 2.8, 5.6, and 8.0 K-factor, upright, pendent, and recessed pendent sprinkler (TY1151, TY1251, TY4851, TY4951, TY4151, TY4251, TY3151, TY3251), see TFP151 for technical information and listing details
TFP151
Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage, K-factor = 2.8, 5.6, and 8.0
TFP152
Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage, K-factor = 5.6
TFP161
Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage, K-factor = 5.6
Series RFII Standard Coverage Sprinkler
5.6 K-Factor Royal Flush II Concealed Pendent Sprinkler
- Orientation: Concealed pendent design for a clean, unobtrusive finish
- K-Factor: 5.6 for reliable and efficient water flow
- Temperature Rating: Up to 200°F
- Response Type: Available in quick and standard response options
- Concealed in an enclosed escutcheon plate with flat cover
- For 5.6 K-Factor Royal Flush II concealed pendent sprinklers quick & standard response, standard coverage (TY3531, TY3551), see TFP181 for technical information and listing details
- UL and C-UL Listed, FM, NYC, VdS, and LPCB Approved
TFP181
Royal Flush II Concealed Pendent Sprinklers, Quick & Standard Response, Standard Coverage, K-factor – 5.6
Series TY-FRB Sprinklers
- Orientations: Upright, pendent, recessed pendent, horizontal sidewall, recessed horizontal sidewall, and vertical sidewall
- K-Factor: Up to 8.0 for efficient water discharge
- Temperature Rating: Up to 286°F
- Response Type: Quick response
- UL and C-UL Listed; FM, NYC, VdS, and LPCB Approved
- For 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers (TY1131, TY1231, TY2131, TY2231, TY3131, TY3231, TY4831, TY4931, TY4131, TY4231), see TFP171 for technical information and listing details
- For 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers (TY3431, TY3331), see TFP176 for technical information and listing details
- For 5.6 K-factor upright, pendent, and recessed pendent sprinklers (TY313, TY323), see TFP172 for technical information and listing details
TFP171
Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage, K factor = 2.8, 4.2, 5.6, and 8.0
TFP172
5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage
TFP176
Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage, K-factor = 5.6