Input and Output Units

We offer a full range of input and output units to suit a wide variety of applications, including high-risk environments.

Ex n, Ex ia and Ex d approved options are available, ensuring safe and reliable operation. All units feature automatic addressing and built-in short-circuit protection, and are compatible with our interactive fire and gas detection systems, unless stated otherwise.

Available Products

autrokeeper bn 180

AutroKeeper BN-180

For Dual Safety solution on AutroSafe systems.

monitoring input unit bn 201

Monitoring input unit BN-201

The unit is connected to the interactive detector loop, and is used for monitoring of fault or other signal contacts from external equipment.

extinguishing control unit bn 221/01

Extinguishing control unit BN-221/01

Unit for monitoring and control of extinguishing equipment. IP67. For AutroSafe/AutroSafe IFG only.

extinguishing control unit bn 221/01

Monitored output unit with 7A relay BN-221/02

Addressable sounder that is connected directly to the detection loop.

input unit bn 300

Input unit BN-300

Unit with one monitored input for connection of external alarm contacts etc.With SelfVerify.

input unit bn 300m

Input unit BN-300M

Modular input unit with one monitored input, for connection of external alarm contacts etc. Mounting on DIN rail. With SelfVerify.

auto draft

Single monitored input unit BN-303

For interfacing switches and 3rd party detectors with relay outputs to Autronica’s interactive fire detection systems. For Autroprime (1.1.0 or newer versions) and AutroSafe (4.3.1 or newer versions). With SelfVerify.

auto draft

Single monitored input/output unit BN-304

For interfacing and controlling external units to Autronica’s interactive fire detection systems. For Autroprime (version 1.1.0 or newer) and AutroSafe (version 4.3.1 or newer). With SelfVerify.

dual monitored input/output unit bn 305

Dual monitored input/output unit BN-305

For interfacing and controlling external units to Autronica’s interactive fire detection systems. With SelfVerify.

dual monitored input/output unit bn 305 2

Dual monitored input/output unit BN-305-2

For interfacing and controlling external units to Autronica’s interactive fire detection systems, DIN-rail mounted. With SelfVerify.

control and monitoring unit bn 305 d

Control and monitoring unit BN-305-D

For interfacing external units to our fire detection systems, DIN rail mounted.

monitored fire alarm device control unit bn 307

Monitored fire alarm device control unit BN-307

FAD control unit.

monitored fire alarm device control unit bn 307

Single relay output unit BN-310

Loop relay output unit with 1 potential free output. The unit is used for door release, sprinkler control/functions, and control of fire dampers. With SelfVerify.

monitored fire alarm device control unit bn 307

Interface unit BN-320

Interface unit for detectors with special. Each unit with its own address. With SelfVerify.

monitored fire alarm device control unit bn 307

Door control unit BN-320/2

Interactive door control unit, for control and monitoring of fire doors. With SelfVerify.

monitored fire alarm device control unit bn 307

Monitoring and control unit BN-320/4

For monitoring and/or control of various external equipment, such as control of fire dampers, ventilation valves, fans, lifts, plus fire and smoke hatches. With SelfVerify.

monitored fire alarm device control unit bn 307

Sprinkler control unit BN-320/5

For monitoring and control from sprinkler systems. With SelfVerify

conventional loop interface module bnb 330a

Conventional loop interface module BNB-330A

Designed to monitor conventional fire detectors of the current increase type and to convey their status to the fire alarm control panel.

conventional loop interface module bnb 331

Conventional loop interface module BNB-331

2-wire interface unit for interfacing conventional detectors and manual call points onto Autronica’s interactive fire detection systems. DIN rail mounted.

input unit bn 500/ex

Input unit BN-500/EX

With one monitored input, for connection of external alarm contacts etc. Approved for use in hazardous areas. With SelfVerify.

input unit bn 500/ex

Input unit BN-500/N

With one monitored input, for connection of external alarm contacts etc. Approved for use in hazardous areas, zone 2. With SelfVerify.

cable glands for ingress protection level 67

Cable glands for Ingress protection level 67

M20-1.5